Insulation, earthing, fuses and circuit breakers
The three mains wires
| Wire | Colour | Job |
|---|---|---|
| Live | brown | carries the alternating voltage from the supply — dangerous |
| Neutral | blue | completes the circuit, near 0 V |
| Earth | green and yellow stripes | safety wire, carries current away if there is a fault |
Insulation
The wires are coated in plastic, which is an insulator (very high resistance). Plugs, sockets and cable coverings are plastic so that current cannot pass through to the user if they touch them. Damaged or frayed insulation exposes the live wire and risks an electric shock.
Double insulation
Some appliances (hairdryers, plastic kettles, vacuum cleaners, electric drills) have a plastic outer casing as well as insulated wires — two layers of insulation. There is no exposed metal for the live wire to touch, so the user can never be connected to the live wire.
A double insulated appliance needs no earth wire — it is fitted with a two-core cable. It is marked with the symbol of a square inside a square.
Earthing
Used on appliances with a metal case (cookers, washing machines, toasters).
The metal case is connected to the earth wire, which is a low resistance path to the ground.
If the live wire works loose and touches the metal case:
- A very large current flows from live, through the case, down the earth wire.
- This large current melts the fuse (or trips the circuit breaker).
- The live wire is disconnected, so the case is no longer live and the user cannot get a shock.
The earth wire by itself does not protect you — it works with the fuse.
Fuses
A fuse is a thin piece of wire inside a cartridge, fitted in the plug, in the live wire.
If the current rises above the fuse rating, the heating effect melts the fuse wire, breaking the circuit and disconnecting the live wire from the appliance. This protects the appliance and its cable from overheating and catching fire, as well as protecting the user.
A blown fuse must be replaced.
Circuit breakers
A circuit breaker is an automatic switch that trips (switches off) when the current is too large.
| Fuse | Circuit breaker | |
|---|---|---|
| Action | wire melts | switch trips open |
| Speed | slower | operates faster |
| After a fault | must be replaced | can be reset and reused |
Common mistake: writing that the fuse is fitted in the neutral wire. It must be in the live wire — otherwise the appliance would still be connected to the live supply after the fuse blew.
Examiner tip. Questions on earthing want a sequence, not a single word. Write: live touches case → large current flows through the earth wire → fuse melts/blows → circuit broken → case no longer live. Answers that just say 'the earth wire takes the electricity away safely' pick up at most one mark.