Using A, V and W correctly: prefixes and conversions
Prefixes you will meet
All three units take the standard prefixes. You must convert to the plain unit before using a formula.
| Prefix | Symbol | Multiply by | Example |
|---|---|---|---|
| milli- | m | ÷ 1000 (×10⁻³) | 250 mA = 0.250 A |
| kilo- | k | × 1000 (×10³) | 2.5 kW = 2500 W |
| mega- | M | × 1 000 000 (×10⁶) | 1.2 MW = 1 200 000 W |
Note the capitals: mA is milliamperes, MA would be megaamperes. kW has a small k and a capital W.
Converting — worked checks
- 45 mA → 0.045 A (divide by 1000)
- 0.30 A → 300 mA (multiply by 1000)
- 3.0 kV → 3000 V
- 1500 W → 1.5 kW
Putting them together
A lamp carries a current of 500 mA from a 6.0 V supply. Find the power.
- Convert first: 500 mA = 0.500 A
- P = I × V = 0.500 × 6.0 = 3.0 W
If you had used 500 instead of 0.500 you would have got 3000 W — a lamp brighter than a kettle, which should look obviously wrong.
Common mistake: putting milliamps straight into a formula. Always convert mA → A before you multiply or divide.
Three habits that pick up marks
- Always write the unit next to the number in a final answer — "3.0" on its own can be refused.
- Use the correct symbol, not a word mixed with a symbol: write 3.0 W, not "3.0 Watts/s".
- Sanity-check the size: currents in school circuits are usually a fraction of an amp up to a few amps; lab supplies are a few volts; lab components are a few watts.
Examiner tip. The most common unit error is not converting prefixes — especially mA. Before you press a single calculator button, rewrite every value in plain A, V and W, then substitute. It costs five seconds and saves the whole calculation.